반응형 업무이야기320 Juniper EX4200 VLAN Configuration Juniper EX4200 VLAN Configurationhttp://www.juniper.net/techpubs/en_US/junos11.4/topics/task/configuration/bridging-vlans-ex-series-cli.htmlConfiguring VLANs for EX Series Switches (CLI Procedure)EX Series switches use VLANs to make logical groupings of network nodes with their own broadcast domains. VLANs limit the traffic flowing across the entire LAN and reduce collisions and packet retransmi.. 2021. 1. 25. Could you please share us the below listed information to proceed further on this case. Could you please share us the below listed information to proceed further on this case.“show diag detail” output.SysdumpLog files upload allHow to collect Sysdump:Example :FreeUser-10-4 [default: master] # debug generate dumpGenerated dump sysdump-FreeUser-10-4-20190410-060522.tgz.gpgMSWMN14GLBS102 (config) # show file debug-dumpsysdump-MSWMN14GLBS102-20120412-123916.tgz.gpgsysdump-FreeUser-10-4.. 2021. 1. 25. Juniper EX S/W Factory Reset Juniper EX S/W Factory Reset[edit]user@switch# load factory-default[edit]user@switch# run request system zeroize[edit]user@switch# delete system commit factory-settings[edit]user@switch# set system root-authentication plain-text-password[edit]user@switch# commitFirmware Upgraderoot@SW2# run request system software add /var/tmp/jinstall-ex-4300-14.1X53-D45.3-domestic-signed.tgz rebootroot@SW2# ru.. 2021. 1. 25. To set up GRIP successfully, it is advised that you check the inline functions of each HC2 separately. To set up GRIP successfully, it is advised that you check the inline functions of each HC2 separately.https://gigamoncp.force.com/partnercommunity/s/article/HC2-GRIP-Configuration-example#loadedA. Set up Primary without GRIPa. ensure secondary is wire only (i.e physical bypass = enable)b. take primary out of bypass, configure all ports and forward inline traffic to inline toolOn secondary: inlin.. 2021. 1. 25. Alteon-5208 Default Config Alteon-5208 Default ConfigStandalone ADC - Main# c[Configuration Menu]sys - System-wide Parameter Menuport - Port Menupmirr - Port Mirroring Menubwm - Bandwidth Management Menul2 - Layer 2 Menul3 - Layer 3 Menuslb - Server Load Balancing (Layer 4-7) Menusecurity - Security Menudump - Dump current configuration to script fileptcfg - Backup current configuration to FTP/TFTP/SCP servergtcfg - Resto.. 2021. 1. 20. Fortinet FortiSandbox Shell mode FortiSandbox Shell modeThen in cli, run 'fnsysctl shell', login with 'fsa_support/Support@FSA1’cd /drive0/public/clean/20170623/04/2841/3404914715784600920sandbox-jobs-move -e3404914715784600920.metastrings 3404914715784600920.metatar -czvf kbbank.gz *cp kbbank.gz /web/static/https://FSA_IP/static/파일명reset-bulidnoPlease provide me more information as below ;Go to FortiView > File Scan Search and.. 2021. 1. 20. Fortinet FortiSandbox Clustering Setting sample [FortiSandbox Clustering Setting]Step 1 - Configure the masterConfigure the port IP addresses and gateway address with the following commands:set port1-ip 192.168.1.99/24set port2-ip 192.168.2.99/24set port3-ip 192.168.3.99/24set default-gw 192.168.1.1Configure the device as the master node and its cluster fail-over IP for Port1 with the following commands:hc-settings -sc -tM -nMasterA -cTestHCs.. 2021. 1. 20. Gigamon ASF (Buffered) Email Attachment Content-Disposition 1000byte & (Unbuffered) Yahoo MSG ASF (Buffered) Email Attachment Content-Disposition 1000byte & (Unbuffered) Yahoo MSGhc2-1 (config) # show run##Running database "initial"Generated at 2019/06/19 05:51:13 +0900Software version on which this output was taken: GigaVUE-OS 5.4.00 98411 2018-07-24 02:03:59Hostname: hc2-1##Note: If you are not an admin user some command invocations may be omittedbecause you do not have permissions to .. 2021. 1. 20. Juniper SRX 설정 방법 (CLI) SRX 설정 방법 (CLI)설정 확인(operation 모드)show configuration | display set | match “찾을 문자 또는 숫자”어드레스 추가(configure 모드)set security zones security-zone untrust address-book address 222_231_7_233 222.231.7.233/32set security zones security-zone trust address-book address 2_2_2_2 2.2.2.2/32어드레스 그룹 추가(configure 모드)set security zones security-zone untrust address-book address-set 222_231_7_233/222_231_7_234 a.. 2021. 1. 20. Gigamon Active Visibility (Condition & Action Lists) Gigamon Policy (Active Visibility)gigamon-0200fd (config policy alias test3) # condition add ? Add a condition to the policyGsCpuUtilHighGsCpuUtilLowGsHbStatusDownGsHbStatusUpGsPktBufThHighGsPktBufThLowGsPktDropRateHighGsPktDropRateLowGsRxPktErrorHighGsRxPktErrorLowGsRxPktRateHighGsRxPktRateLowInlineToolDownInlineToolReadyInlineToolUpPortDownPortRxBufferHighPortRxBufferLowPortRxDiscardsHighPortR.. 2021. 1. 20. Gigamon Controlled GigaStream Configuration Controlled GigaStream ConfigurationTo configure a controlled tool GigaStream, specify hash size and hash bucket ID, using the prefix mode. Refer to the following example:StepDescriptionCommandConfigure ports using type tool for controlled GigaStream.(config) # port 1/3/q4..q6 type toolConfigure a controlled GigaStream. This uses the prefix mode to configure all parameters.(config) # gigastream a.. 2021. 1. 20. Gigamon IP Tunnel Receiving End Configuration IP Tunnel Receiving End Configurationport 1/1/x1 type networkport 1/1/x5 type toolgsgroup alias GS51 port-list 1/5/e1tunneled-port 1/1/x1 ip 192.168.51.80/24 gateway 192.168.51.1 mtu 9600 port-list GS51gsop alias Remote2HQtunnel tunnel-recap type grip portdst 8001 port-list GS51map alias FieldCallCtrDB# comment "Field Call Center database traffic received at HQ"# use gsop Remote2HQTunnel# rule a.. 2021. 1. 18. Gigamon IP Tunnel Sending End Configuration IP Tunnel Sending End Configurationport 1/1/x1 type networkport 1/1/x5 type toolgsgroup alias GS51 port-list 1/5/e1tunneled-port 1/1/x5 ip 172.16.10.88/24 gateway 172.16.10.1 mtu 9600 port-list GS51gsop alias Chicago2HQ tunnel-uncap type gmip porters 8000 protest 8001 ipdst 192.168.51.80 port-list GS51map alias ChicagoDBtoHQ# comment "Chicago Call Center Database traffic sent to HQ"# use gsop Ch.. 2021. 1. 18. Docker 기본 명령어 https://cultivo-hy.github.io/docker/image/usage/2019/03/14/Docker정리/https://subicura.com/2017/02/10/docker-guide-for-beginners-create-image-and-deploy.htmlhttps://javacan.tistory.com/entry/docker-start-6-docker-image-layerhttps://ifuwanna.tistory.com/249컨테이너 목록 확인하기 (ps)docker ps [OPTIONS]컨테이너 중지하기 (stop)docker stop [OPTIONS] CONTAINER [CONTAINER...]도커 ID의 전체 길이는 64자리 입니다. 하지만 명령어의 인자로 전달할 때는 전부.. 2021. 1. 18. [MacOS] Mac LaunchPad 사이즈 조절 Mac LaunchPad 사이즈 조절defaults write com.apple.dock springboard-columns -int 11defaults write com.apple.dock springboard-rows -int 9killall Dock배경화면 경로 보이기defaults write com.apple.dock desktop-picture-show-debug-text -bool TRUE;killall Dockdefaults write com.apple.dock desktop-picture-show-debug-text -bool FALSE;killall Dock 2021. 1. 18. [MacOS] 맥에서 OpenSSL 라이브러리 설치 http://egloos.zum.com/popfly/v/6035802OS X El Capitan부터 OpenSSL이 애플의 SDK에서 제외되었다.맥에서 OpenSSL 프로그래밍을 하려면 소스를 직접 받아 빌드를 해야 한다.이런 불편함을 해소하고, 간편하게 OpenSSL 라이브러리를 얻기 위해 Homebrew를 이용한다.Homebrew 설치하기Homebrew를 설치한 후 터미널에서 아래의 커맨드를 입력한다.$ brew doctorHomebrew의 실행 환경이 잘 되었는지 검사한다.이상이 없으면 경고 메시지가 나오지 않는다.내 경우엔 아래처럼 경고가 나왔다.이를 해결하려면 터미널에서 아래의 커맨드를 입력한다.계정이름에는 맥에 로그인한 계정이름을 넣는다.$ sudo chown -R 계정이름:admin /usr.. 2021. 1. 18. Gigamon Resiliency for Inline Protection (GRIP) You can configure Gigamon Resiliency for inline protection on H Series nodes (GigaVUE-HC1, GigaVUE-HC2, and GigaVUE-HC3). Example 18 is an inline bypass solution for GRIP using TAP-HC1-G10040 modules on GigaVUE-HC1 with copper ports. The same instructions apply to GigaVUE-HC2 and GigaVUE-HC3.Note: On the GigaVUE-HC2, the configuration steps will be the same as in this example, but the network po.. 2021. 1. 18. Gigamon Maps to Individual Inline Tool Group Members Example 17 is an inline bypass solution on GigaVUE-HC2 for an inline tool group with four tools. It is similar to Example 16: Asymmetrical Hashing in Inline Tool Group, but has four rule-based inline maps, one to each individual member of the inline tool group. In Example 17, asymmetrical hashing is used, but the hashing could also be symmetrical. The hashing only applies to the traffic sent to .. 2021. 1. 18. Gigamon Asymmetrical Hashing in Inline Tool Group Example 16 is an inline bypass solution on GigaVUE-HC2 for an inline tool group with four tools. The inline tool group uses asymmetrical hashing (unlike Example 5: Inline Tool Group (N+1) Redundancy which uses symmetrical hashing). The hashing is based on the source IP address for side A and the destination IP address for side B.A rule-based map (vlan 200) is configured from the inline network t.. 2021. 1. 18. Gigamon OOB Maps Originating from Inline Network Group Example 15 expands on Example 14 by combining out-of-band (OOB) maps with a map passall originating from an inline network group on GigaVUE-HC2.When the source port of an OOB map is associated with an inline network group, only one port is supported in the port list. In this case, multiple OOB maps are needed because each OOB map only accepts one inline network port as the input (the from argume.. 2021. 1. 18. Gigamon OOB Maps Originating from Inline Network Example 14 combines out-of-band (OOB) maps with a map passall originating from an inline network on GigaVUE-HC2. In Example 14, the map passall sends all traffic to the inline tool. The OOB rule-based map sends traffic to an OOB tool.When the source port of an OOB map is associated with an inline network, multiple source ports are supported in the port list (the from argument of the map command).. 2021. 1. 18. 이전 1 2 3 4 5 6 7 8 ··· 16 다음 반응형