반응형
SMALL

 



- Node 0 
   # set chassis cluster cluster-id 1 node 0 reboot
- Node 1
   # set chassis cluster cluster-id 1 node 1 reboot


set groups node0 system host-name srx1500-1
set groups node0 interfaces fxp0 unit 0 family inet address 192.16.35.46/24
set groups node1 system host-name srx1500-2
set groups node1 interfaces fxp0 unit 0 family inet address 192.16.35.47/24
set groups node0 system backup-router <backup next-hop from fxp0> destination <management network/mask>
set groups node1 system backup-router <backup next-hop from fxp0> destination <management network/mask>
set apply-groups "${node}"
set interfaces fab0 fabric-options member-interfaces ge-0/0/1
set interfaces fab1 fabric-options member-interfaces ge-7/0/1
set chassis cluster redundancy-group 0 node 0 priority 100
set chassis cluster redundancy-group 0 node 1 priority 1
set chassis cluster redundancy-group 1 node 0 priority 100
set chassis cluster redundancy-group 1 node 1 priority 1
set chassis cluster redundancy-group 1 interface-monitor ge-0/0/5 weight 255
set chassis cluster redundancy-group 1 interface-monitor ge-0/0/4 weight 255
set chassis cluster redundancy-group 1 interface-monitor ge-7/0/5 weight 255
set chassis cluster redundancy-group 1 interface-monitor ge-7/0/4 weight 255
set chassis cluster reth-count 2
set interfaces ge-0/0/5 gigether-options redundant-parent reth1
set interfaces ge-7/0/5 gigether-options redundant-parent reth1
set interfaces reth1 redundant-ether-options redundancy-group 1
set interfaces reth1 unit 0 family inet address 203.0.113.233/24
set interfaces ge-0/0/4 gigether-options redundant-parent reth0
set interfaces ge-7/0/4 gigether-options redundant-parent reth0
set interfaces reth0 redundant-ether-options redundancy-group 1
set interfaces reth0 unit 0 family inet address 198.51.100.1/24
set security zones security-zone Untrust interfaces reth1.0
set security zones security-zone Trust interfaces reth0.0 


Verification
>show chassis cluster status
>show chassis cluster interfaces
>show chassis cluster statistics
>clear chassis cluster statistics
>show chassis cluster control-plane statistics
>show chassis cluster data-plane statistics
>show chassis cluster status redundancy-group 1
>show chassis cluster information configuration-synchronization
> show log jsrpd
>show log chassisd
>show log messages
>show log dcd
>show traceoptions

 

 

반응형
LIST

'업무이야기 > Security' 카테고리의 다른 글

AhnLab Network Solutions  (0) 2022.11.21
FortiGate FSSO 설정  (0) 2022.08.10
Juniper SRX Policy-Based IPSec VPN  (0) 2021.08.26
Juniper SRX Routed-Based IPSec VPN  (0) 2021.08.26
DefensePro CLI  (0) 2021.04.26
반응형
SMALL

Juniper SRX request chassis cluster failover redundancy-group

date_range22-Feb-21

arrow_backward arrow_forward

Syntax

content_copy zoom_out_map

request chassis cluster failover node node-number redundancy-group redundancy-group-number

Description

For chassis cluster configurations, initiate manual failover in a redundancy group from one node to the other, which becomes the primary node, and automatically reset the priority of the group to 255. The failover stays in effect until the new primary node becomes unavailable, the threshold of the redundancy group reaches 0, or you use the request chassis cluster failover reset command.

After a manual failover, you must use the request chassis cluster failover reset command before initiating another failover.

Options

  • node node-number—Number of the chassis cluster node to which the redundancy group fails over.
  • Range: 0 or 1
  • redundancy-group group-number—Number of the redundancy group on which to initiate manual failover. Redundancy group 0 is a special group consisting of the two Routing Engines in the chassis cluster.
  • Range: 0 through 255

Required Privilege Level

maintenance

Output Fields

When you enter this command, you are provided feedback on the status of your request.

Sample Output

request chassis cluster failover redundancy-group

content_copy zoom_out_map

user@host> request chassis cluster failover redundancy-group 0 node 1 {primary:node0} user@host> request chassis cluster failover redundancy-group 0 node 1 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Initiated manual failover for redundancy group 0

Release Information

Command introduced in Junos OS Release 9.0.

RELATED DOCUMENTATION

 